HOME SERVICES EXPERIENCE STAFF ABOUT US CONTACT BROCHURES

Alternate Source Term (AST) Experience

    Full AST Implementation Project Experience

 Plant

 Type

Accidents

Analyzed

 c/Q Analysis

Pool pH Analysis

 Notes

NRC

Approval

Duane Arnold

BWR

LOCA, MSLB, CRDA, FHA

Yes, PAVAN & ARCON96

Yes

Developed in conjunction with Extended Power Uprate

Yes

Brunswick

BWR

LOCA, MSLB, CRDA, FHA

Yes, PAVAN & ARCON96

Yes

Developed in conjunction with Extended Power Uprate

Yes

River Bend

BWR

MSLB, CRDA, FHA

No

Yes

Also review of client’s LOCA analysis.

Yes

H B Robinson

PWR

LOCA, MSLB, SGTR, Locked Rotor, RCCA Withdrawal, WGDT Rupture, FHA

Yes, ARCON96

Yes

Developed in conjunction with Appendix K Power Uprate.  Also LOCA updates and pH calculations for sump buffer modification project.

Yes

Monticello

BWR

LOCA, MSLB, CRDA, FHA

Yes, PAVAN & ARCON96

Yes

Developed in conjunction with Extended Power Uprate

Yes

    Additional AST Project Experience

 Plant

 Type

Accidents Analyzed

 c/Q Analysis

Pool pH Analysis

Notes

Korea Power Engineering Co.

PWR

AST Analysis Consulting

N/A

N/A

Provided consulting in the preparation of PWR AST analysis calculations

Fermi 2

BWR

LOCA

Yes, PAVAN & ARCON96

No

Third party review of AST LOCA analyses.

Susquehanna

BWR

LOCA, MSLB, CRDA, FHA

No

No

Preliminary calculations

Cooper

BWR

LOCA

No

No

Provided Condenser Iodine Removal Models

 

Home   Services   Experience   Staff   About Us   Contact   Brochures

Copyright © 1999-2017, Applied Analysis Corp.